Overview of the APC NetShelter APDU11250SM
The APC NetShelter APDU11250SM is a robust 11.5kW 3-Phase 415V 20A Switched Metered Rack PDU, designed to meet the high power demands of modern data centers and server rooms. Priced competitively in Bangladesh, this PDU offers a reliable solution for managing power distribution effectively. With a weight of 7.7 kg and dimensions of 1490 × 75 × 56 mm, it is compact yet powerful. The 3-meter cable length ensures flexibility in installation, while the environmental rating of 5-95% RH (non-condensing) makes it suitable for various conditions.
APC NetShelter APDU11250SM in Bangladesh
In Bangladesh, the APC NetShelter APDU11250SM is an ideal choice for businesses looking to enhance their power management capabilities. As data centers grow in size and complexity, the need for efficient power distribution becomes paramount. This PDU supports local infrastructure with its 400/415V AC input voltage, making it compatible with existing systems. The ability to remotely monitor and switch outlets adds a layer of convenience that is essential for IT professionals managing multiple devices. With its certifications from CE, CSA, EN, FCC, UL, and TAA, buyers can trust in its quality and compliance with international standards.
APC NetShelter APDU11250SM Performance and Power
The performance of the APC NetShelter APDU11250SM is defined by its impressive specifications. Operating at 11.5 kW, it can handle significant loads, making it suitable for high-demand environments. The 20A input current and 3-phase configuration ensure balanced power distribution, reducing the risk of overload. With 48 outlets, including a mix of C13/C15 and C19/C21 types, it provides ample connectivity for various devices. The PDU operates effectively within a temperature range of -5°C to 60°C, ensuring reliability even in challenging conditions.
APC NetShelter APDU11250SM Best for
This PDU is best suited for IT managers, data center operators, and businesses that require robust power management solutions. Its features cater to those who need to monitor power usage closely and switch outlets remotely. However, smaller setups or those with minimal power needs may find this model excessive. For those looking for a reliable, high-capacity PDU, the APC NetShelter APDU11250SM is an excellent investment.
Detailed Analysis of APC NetShelter APDU11250SM
- Power Capacity: 11.5 kW / 11.5 kVA + Ideal for high-demand applications requiring substantial power.
- Input Voltage: 400/415V AC + Compatible with standard data center power systems in Bangladesh.
- Number of Outlets: 48 + Provides extensive connectivity for multiple devices.
- Remote Monitoring: Yes + Enables real-time tracking of power usage and outlet status.
- Mounting Option: Vertical, Side-Mount + Flexible installation options for various rack setups.
- Environmental Rating: 5–95% RH, Non-Condensing + Suitable for diverse operational environments.
- Network Connectivity: Gigabit Ethernet, USB + Facilitates easy integration with existing network systems.
- Input Plug Type: IEC 60309 20A 3P+N+PE (520P6) + Ensures compatibility with standard power sources.
User Experience of the APC NetShelter APDU11250SM
Using the APC NetShelter APDU11250SM in a daily environment is straightforward. The setup process is user-friendly, allowing for quick installation in various configurations. Users appreciate the remote monitoring feature, which simplifies power management. However, some may find the unit slightly heavier than expected, which could complicate installation in tight spaces. Overall, the PDU operates quietly and efficiently, with minimal heat generation, making it a reliable choice for continuous use.
Benefits of the APC NetShelter APDU11250SM
Owning the APC NetShelter APDU11250SM brings several long-term benefits. Its high power capacity ensures that businesses can scale their operations without worrying about power limitations. The remote monitoring and switching capabilities enhance operational efficiency, allowing for proactive management of power usage. Additionally, the robust construction and environmental ratings mean that this PDU can withstand various conditions, ensuring longevity and reliability. Users will find that the extensive outlet options provide flexibility in connecting multiple devices, making it a versatile addition to any data center.
Key Features of APC NetShelter APDU11250SM
- Remote Switching: Yes = Control outlets from anywhere, enhancing convenience.
- Environmental Rating: 5–95% RH = Reliable operation in diverse conditions.
- Input Frequency: 50/60 Hz = Compatible with global power standards.
- Storage Temperature: -25°C to 65°C = Suitable for varied storage environments.
- AI Compatibility: Yes = Perfect for modern, high-density racks.
- Form Factor: 0U = Maximizes space efficiency in racks.
Best Practices for Maintaining the APC NetShelter APDU11250SM
To maintain the APC NetShelter APDU11250SM effectively, regular cleaning is essential to prevent dust buildup, especially in humid environments like Bangladesh. Ensure that the PDU is installed in a well-ventilated area to avoid overheating. Periodically check the connections and cables for wear and tear, and ensure that the unit is operating within its specified temperature range. Using surge protectors can help safeguard against voltage fluctuations, which are common in local electrical systems.
Where I Can Found APC NetShelter APDU11250SM In Bangladesh
You can purchase the APC NetShelter APDU11250SM from Crystal Computers, a trusted name in the Bangladeshi tech market. Visit our physical store in Dhaka or shop online at crystalcomputers.com.bd. We provide reliable after-sales service across Bangladesh, handling warranty claims, technical issues, and product support directly through our team. Our commitment to customer satisfaction ensures that you receive the best service and support for your purchase.